Electrical tests
Diagnostic electrical testing for transformers and substations
Each test isolates a different failure mode. We run them with Omicron and Megger instrumentation, correct for temperature and deliver a protocol compared against standards and asset history.
Transformer turns ratio test (TTR)
Verifies the turns ratio between high- and low-voltage windings to detect shorted turns, tap-changer faults and connection errors.
Ver másInsulation power factor and Tan Delta
Measurement of dielectric losses in transformer and bushing insulation to detect moisture, contamination and paper-oil ageing before they cause failure.
Ver másInsulation resistance and polarization index
Measurement of insulation resistance with a megohmmeter and calculation of absorption and polarization indices to assess moisture and cleanliness of the dielectric system.
Ver másDissolved gas analysis in oil (DGA)
Chromatography of the insulating oil to detect incipient faults — arcing, partial discharge and hot spots — from the gases dissolved in the oil, without de-energizing the transformer.
Ver másSweep frequency response analysis (SFRA)
SFRA test that detects mechanical deformation and displacement of windings and core — invisible to conventional electrical tests — after short circuits, transport or earthquakes.
Ver másTransformer winding resistance test
Measurement of the DC resistance of windings to detect loose connections, broken strands and bad tap-changer contacts.
Ver másTransformer excitation current test
Measurement of the no-load current the transformer draws to detect shorted turns, core defects and tap-changer faults.
Ver másPhysicochemical oil analysis
Battery of physical and chemical tests on transformer oil to assess its condition and decide reconditioning, regeneration or replacement.
Ver másMoisture in oil (Karl Fischer)
Measurement of water content in transformer oil by Karl Fischer titration — moisture is one of the main accelerators of insulation ageing.
Ver másFuran analysis (paper ageing)
Measurement of furanic compounds in oil to estimate the ageing of the solid insulation (paper) — the part of a transformer that cannot be renewed.
Ver másPCB (askarel) content in oil
Testing transformer oil for polychlorinated biphenyls (PCB / askarel) — a regulatory and environmental compliance requirement before servicing or disposal.
Ver másGround (earthing) system measurement
Measurement of the resistance and integrity of a substation grounding system to ensure personnel safety and correct protection operation.
Ver másSF6 circuit breaker testing
Testing of SF6 high-voltage circuit breakers: gas quality, contact resistance, timing and mechanism, to ensure reliable interruption.
Ver másTalk to a transformer specialist
Tell us about your asset and we'll respond with a diagnosis and a tailored quote — not generic pricing.