Acetylene in transformer oil (DGA)

Duration
36 seconds
Language
Spoken in English
Captions
English captions, switchable from the player
Published
Published November 12, 2026

What is behind this video

An arc inside a cement-plant transformer leaves a signature in the oil: acetylene. Per IEEE C57.104-2019, it forms in meaningful amounts only near 1000 °C. If nothing inside is meant to arc, there should not be any. One sample is not enough; what matters is whether the value is rising.

It is the signature of an arc, not simply a sign of old oil. The arc breaks down the oil and leaves dissolved acetylene. Per IEEE C57.104-2019, that gas forms in meaningful amounts only near one thousand degrees. If nothing inside the tank is meant to arc, it should not be present.

Near one thousand degrees, according to IEEE C57.104-2019. That is why it is associated with an arc and not with milder heating. The video uses that figure from the standard; it is not an invented lab threshold, and it is not an automatic diagnosis from a single isolated number.

No. The video is explicit: one sample is not enough. What matters is whether the acetylene is rising over time. A single value, without trend or context for the unit, is not enough to conclude. Comparison against the history is what turns dissolved-gas analysis into a decision tool.

The references behind what the video says are: IEEE C57.104-2019: acetylene forms in meaningful amounts only near 1000 °C; units without devices intended to arc should not generate C2H2.

This piece is animation and typography: it does not show TEVKO personnel. The figures are the ones in the script and can be checked against this page and the linked pages.

Transcript — English audio

How do you know there was an arc inside a cement plant's transformer if nobody saw it? The oil tells you.

The arc breaks down the oil and leaves a dissolved gas: acetylene. It's like a breathalyzer: it didn't see you drink, but your breath gives you away.

Per IEEE, it forms in meaningful amounts only near 1000 °C. If nothing inside is meant to arc, there shouldn't be any.

But watch out: one sample isn't enough; what matters is whether it's rising. So it's not old oil. It's an arc's signature.

Comment ACETYLENE and we'll tell you how to read your analysis.

The same captions ship as a WebVTT track inside the player. The spoken close invites a comment on the network where the video was posted. On this page the contact is ventas@tevko.com and the phone +52 33 2101 7241.

Questions this video answers

What does acetylene in transformer oil indicate?

It is the signature of an arc, not simply a sign of old oil. The arc breaks down the oil and leaves dissolved acetylene. Per IEEE C57.104-2019, that gas forms in meaningful amounts only near one thousand degrees. If nothing inside the tank is meant to arc, it should not be present.

At what temperature does acetylene form in meaningful amounts?

Near one thousand degrees, according to IEEE C57.104-2019. That is why it is associated with an arc and not with milder heating. The video uses that figure from the standard; it is not an invented lab threshold, and it is not an automatic diagnosis from a single isolated number.

Is one DGA sample enough to decide?

No. The video is explicit: one sample is not enough. What matters is whether the acetylene is rising over time. A single value, without trend or context for the unit, is not enough to conclude. Comparison against the history is what turns dissolved-gas analysis into a decision tool.

Related pages

Technical content reviewed by TEVKO Technical Management · last reviewed: November 12, 2026

Request a technical assessment

Write to our sales inbox with the following and we will tell you what the next step is:

  • The nameplate: rating, voltage, make and serial number.
  • The location of the installation.
  • The problem the unit presents, or the event that occurred.
ventas@tevko.com