TEVKO
Technician in dielectric gloves working an insulating hot stick at the front of a medium-voltage switchgear line-up, with a dry-type transformer behind

Service

Switchboard maintenance

Maintenance of distribution, control and protection boards and MCC cabinets, with cleaning, re-torque, thermography and testing.

Technician in dielectric gloves working an insulating hot stick at the front of a medium-voltage switchgear line-up, with a dry-type transformer behind
What the photo showsTechnician in dielectric gloves working an insulating hot stick at the front of a medium-voltage switchgear line-up, with a dry-type transformer behind.

Boards and MCC cabinets are where most loose-connection failures begin. We maintain them with cleaning, correct re-torque, insulator and interlock checks, thermography and contact-resistance testing.

A switchboard concentrates connections, busbars and protective devices in a confined space, so a loose or oxidized connection quickly becomes a hot spot and an arcing risk. Preventive maintenance keeps those points under control.

Our scope includes cleaning, re-torque with correct values, inspection of insulators and busbars, verification of mechanical interlocks and grounding, and thermography to locate hot connections before they fail.

For control and protection boards we add functional checks of relays and instrument transformers, closing with a documented protocol.

What we maintain

Distribution boards

Cleaning, re-torque, insulator and busbar inspection, thermography.

When it applies: Periodic preventive maintenance.

Control & protection boards / MCC

Relay and instrument-transformer checks, interlocks and grounding.

When it applies: Verification of control and protection functions.

How we execute the service

Safety

De-energization, verification and grounding.

Inspection

Cleaning, re-torque and thermography.

Testing

Contact resistance and functional checks.

Protocol

Documented report with findings.

Frequently asked questions — switchboard maintenance

Why do switchboards fail?

Most failures start at loose or oxidized connections that overheat. Periodic re-torque and thermography are the most effective prevention.

How often should a board be maintained?

The schedule must be documented against the manufacturer's instructions, asset condition and trends, load, environment, history and failure consequences. Engineering must justify the program and reassess it when anomalies appear; this page does not prescribe a universal interval.

What does the maintenance include?

Cleaning, re-torque, insulator and interlock inspection, grounding verification, thermography and contact-resistance testing, with a documented protocol.

Do you service MCC cabinets?

Yes, motor control center cabinets are part of our switchboard maintenance scope.

Switchboard maintenance in images

Technician opening the door of a control panel with metering instruments and pushbuttons on the front
Technician opening the door of a control panel with metering instruments and pushbuttons on the front
Medium-voltage switchgear room with bushings and current transformers exposed, and a technician beside the test set
Medium-voltage switchgear room with bushings and current transformers exposed, and a technician beside the test set
Control panel with meters, push buttons and a rotary switch.
Control panel with meters, push buttons and a rotary switch.

Related services

Talk to a transformer specialist

Tell us about your asset so we can define the assessment scope and prepare a tailored quote.

Get a quoteEmergency